Load types loads used in design load equations are given letters by type.
Roof live load tables.
The snow load is treated as a live load when you use af pa s tables.
Equation 16 27 equation 16 28.
The fact that snow loads only act part of the year has been used to create the rafter tables.
Compression perpendicular to the grain.
However if the attic is intended for storage the attic live load or some portion should also be considered for the design of.
For roof live loads less than 20 pounds per square foot psf rafter spans and required e values tabulated for 20 psf shall be permitted to be adjusted in accordance with the fol lowing table.
For roof live loads of 12 psf or 16 psf table multiply tabulated multiply required number span by e value by 12 psf 16 psf 12 psf 16 psf.
Except for uni form live loads at roofs all other minimum uniformly distrib uted live loads lo in table 1607 1 are permitted to be reduced in accordance with section 1607 10 1 or 1607 10 2.
The snow load is treated as a live load when you use awc s tables.
1607 10 1 basic uniform live load reduction.
1 for garages.
D dead load l live load l r live roof load w wind load s snow load e earthquake load r rainwater load or ice water load.
2attic loads may be included in the floor live load but a 10 psf attic load is typically used only to size ceiling joists adequately for access purposes.
Notes to table 1607 1 for si.
The fact that snow loads only act part of the year has been used to create the rafter tables.
This information is found in the code book.
Roof live loads largest roof loads typically caused by repair and maintenance pitch rise span lr 20 r1r2 12 lr 20 lr horizontal projection roof live load 16 r 1 r 2 live load reduction factors r 1 accounts for size of tributary area of roof column a t r 2 effect of the roof rise.
L r reduced roof live load per square foot m 2 of horizontal projection supported by the member.
This information is found in the code book.
Loads should be determined in accordance with this chapter.
If your code book says your snow load is 40 psf then you use the 40 psf live load rafter table.
Floors in garages or portions of buildings used for the storage of motor vehicles shall be designed for the uniformly distributed live loads of table 1607 1 or the following concentrated loads.
1 inch 25 4 mm 1 square inch 645 16 mm 2 1 pound per square foot 0 0479 kn m 2 1 pound 0 004448 kn 1 pound per cubic foot 16 kg m 3.
Uniform live loads at roofs are permitted to be reduced in accordance with section 1607 12 2.
The reduction factors r 1 and r 2 shall be determined as follows.
L o unreduced roof live load per square foot m 2 of horizontal projection supported by the member see table 1607 1.
If your code book says your snow load is 40 psf then you use the 40 psf live load rafter table.