A pair of crossed lumberlok strip brace preferred for ease of installation can be classed as one roof plane brace and shall be installed as detailed in this brochure.

Roof plane bracing nz.

This bulletin describes the bracing for subfloors and roofs of buildings within the scope of nzs 3604 2011 timber framed buildings. Wind and earthquakes can generate significant forces on a building. Summarised from branz guideline newsletter october 2014. Bracing demand must be calculated and sufficient bracing incorporated into a building so that the structure can withstand these forces.

Additional valleys or hips that also run from top plate to ridge are counted as one additional brace. There must be at least one roof plane brace in each roof plane. Stainless steel strip brace. For use as bracing or in short lengths as a jointing material.

There must be a minimum of two there is an error in nzs 3604 2011 which requires three that run from top plate to ridge. Roof bracing requirements roof type one roof brace per 50m2 of roof area see rule 8 for minimum requirements one roof brace per 25m2 of roof area see rule 8 for minimum requirements 1. There are several options of roof plane braces see figure 2. The bracing described in this brochure covers both framed roofs and fully trussed roofs.

Roof bracing is unlikely to have any effect if veranda roofs up to 2 m wide are securely fixed to or restrained by the structure of the building. Dormers porches do not require bracing. There must be a minimum of two there is an error in nzs 3604 2011 which requires three that run from top plate to ridge. In a butterfly roof with a central gutter they span between the parapet wall framing and the central gutter in a butterfly roof.

I roof plane brace or ii roof space brace or combination of the two. The trusses will require lateral support at right angles to the length of the trusses at the high end and the roof will also require roof plane bracing and or roof space braces. Branz structural engineers suggest a rule of thumb that where a lightweight veranda roof. Bracing roof framing typically consisted of 4 x 2 100 x 50 mm rafters spaced at 18 450 mm centres.

The highest end shall be considered to be a ridge line for bracing purposes. There are several options of roof plane braces see figure 2. Bu617 subfloor and roof bracing in nzs 3604 2011 buildings. Projects 2 m or less from the building it does not need to have roof bracing.

In a mono pitch roof they span between the front wall parapet framing and the rear wall framing. Strip brace provides an ideal bracing system for walls or roof plane. Additional valleys or hips that also run from top plate to ridge are counted as one additional brace. Roof braces can consist of either.

Roof Trusses Design Framing Construction Pryda New Zealand

Roof Trusses Design Framing Construction Pryda New Zealand

Structural Cost Savings Lightweight Vs Heavyweight Roofing Nz Metal Roofing Manufacturers

Structural Cost Savings Lightweight Vs Heavyweight Roofing Nz Metal Roofing Manufacturers

Https Tropex Co Nz Sites Default Files Product Pdfs Lumberlok 20roof 20bracing 20specification Pdf

Https Tropex Co Nz Sites Default Files Product Pdfs Lumberlok 20roof 20bracing 20specification Pdf

Sloped Dragon Ties Branz Build

Sloped Dragon Ties Branz Build

Source : pinterest.com